Inverter backup time calculator
How long your inverter battery runs what matters in a power cut, and the inverter size that load needs. Two simple questions.
How many watts home appliances use
Typical running watts for an Indian home, and how long one 150Ah tubular battery runs each one on its own.
| Appliance | Watts | 150Ah tubular |
|---|---|---|
| Ceiling fan | 75 W | 15 h 22 min |
| BLDC fan | 30 W | 38 hours |
| LED bulb | 10 W | 115 hours |
| LED tube light | 20 W | 58 hours |
| LED TV (32") | 60 W | 19 h 12 min |
| Wi-Fi router | 15 W | 77 hours |
| Refrigerator | 150 W | 7 h 41 min |
| Laptop | 65 W | 17 h 43 min |
| Desktop PC | 170 W | 6 h 47 min |
| CCTV system | 30 W | 38 hours |
Fridges, pumps and mixers take several times their running watts for a moment when they start, so the inverter needs headroom for them.
How backup time is worked out
- The load. We add up the watts of everything you picked.
- The energy in the battery. Volts × Ah × number of batteries (a 150Ah tubular battery is 12 V × 150 Ah = 1.8 kWh; a 51.2 V 100Ah lithium is 5.12 kWh), using 80% of a tubular battery and 90% of a lithium one, because draining a battery fully shortens its life.
- The inverter's losses. We take 80% inverter efficiency, then divide by the load to get hours.
- The inverter size. Load ÷ 0.8 gives the VA rating to look for.
Inverter backup questions
How long will a 150Ah inverter battery last?
With two fans, three LED bulbs, a tube light, a TV and the Wi-Fi router (275 W), a 150Ah tubular battery runs for about 4 h 11 min. With just one fan and two LED bulbs (95 W) it runs about 12 h 8 min.
Do BLDC fans give more backup?
Yes. A BLDC fan uses about 30 W against 75 W for a regular fan. Swapping two fans in the example above takes the load to 185 W and the backup on a 150Ah tubular battery from 4 h 11 min to about 6 h 14 min.
Tubular or lithium battery: which gives more backup?
Compare batteries by the energy they hold (kWh), not by Ah, because lithium batteries come at higher voltages. A 150Ah tubular battery holds 1.8 kWh and about 80% of it is usable; lithium batteries are sold as 100Ah modules of 12.8 V (1.28 kWh), 25.6 V (2.56 kWh) or 51.2 V (5.12 kWh), about 90% usable. On the same 275 W load: 150Ah tubular about 4 h 11 min, 12.8 V lithium about 3 h 21 min, 51.2 V lithium about 13 h 24 min. The 51.2 V ones need a 48 V solar or hybrid inverter.
What size inverter do I need?
Add up the watts of everything that will run together and divide by 0.8 to get the VA rating, then choose the next size up. 275 W comes to about 350 VA, which any standard home inverter covers. Above about 1,100 VA, home inverters usually need two batteries.
How is inverter backup time calculated?
Battery volts × Ah × the share of the battery that can be used × inverter efficiency, divided by the load in watts. We use 80% for tubular, 90% for lithium and 80% inverter efficiency. For 150Ah tubular and 300 W: 12 × 150 × 0.8 × 0.8 ÷ 300 = about 3 h 50 min.
Want the backup sized for your home?
We check what you want running, the wiring and where the battery goes, and quote a fixed price in writing. Free, with no obligation.
More free calculators
All calculatorsRelated
Inverter and battery installation
Tubular and lithium backup, sized to what you need running.
See the serviceOn-grid, off-grid or hybrid solar
Which kind of solar keeps the lights on in a power cut, and which does not.
Read the guideSolar panel installation
Rooftop plants, with batteries where you need backup.
See the service